Command Reference Manual
3-62
Conexant
100722A
3.2.10 Compatibility Commands
3.2.10.1 &L - Leased Line Operation
This command requests leased line or dial-up operation. This command is provided for compatibility only; no mode change is
performed, dial-up operation continues. The OK response is returned for a valid parameter, but no other action is performed.
The parameter value, if valid, is written to S27 bit 2.
Syntax
&L<value>
Defined Values
<value> Decimal number corresponding to the selected option.
0 Requests dial-up operation. Dial-up operation continues.
Result Codes
OK 0.
ERROR Otherwise.
3.2.10.2 )M - Enable Cellular Power Level Adjustment
This command is included for compatibility only and has no effect other than returning a result code.
Syntax
)M<value>
Defined Values
<value> Decimal number corresponding to the selected option.
0 )M0 command.
1 )M1 command.
2 )M2 command.
Result Codes
OK 0 to 2.
ERROR Otherwise.
3.2.10.3 @M - Initial Cellular Power Level Setting
This command is included for compatibility only and has no effect other than returning a result code.
Syntax
@M<value>
Defined Values
<value> Decimal number corresponding to the selected power setting.
0 @M0 command.
.
.
30 @M30 command.
Result Codes
OK 0 to 30.
ERROR Otherwise.