Command Reference Manual
3-40
Conexant
100722A
3.2.4.4 %U - Select µ-Law or A-Law Codec Type
This command selects µ-Law or A-Law codec type for V.90 and K56flex modulation. This command also stores the selected
setting directly to NVRAM. The default value is country specific.
Syntax
%U<value>
Defined Values
<value> Decimal number corresponding to the selected option.
0 Selects µ-Law.
1 Selects A-Law.
Result Codes
OK <value> = 0 or 1
ERROR Otherwise.
3.2.4.5 B - CCITT or Bell
When the modem is configured to allow either option, the modem will select Bell or CCITT modulation for a line speed
connection of 300 or 1200 bps. Any other line speed will use a CCITT modulation standard. The parameter value, if valid, is
written to S27 bit 6.
Syntax
B<value>
Defined Values
<value> Decimal number corresponding to the selected option.
0 Selects CCITT operation at 300 or 1200 bps during Call Establishment and a
subsequent connection. (Default.)
1 Selects BELL operation at 300 or 1200 bps during Call Establishment and a
subsequent connection.
Result Codes
OK <value> = 0 or 1.
ERROR Otherwise.
Vue de la page 59
1 2 ... 55 56 57 58 59 60 61 62 63 64 65 ... 171 172

Commentaires sur ces manuels

Pas de commentaire