33 API Functions
aaSetCloseDelay
aaSetCloseDelay
Sets the maximum time aaClose() waits for a devices
transmit buffer to drain before flushing the transmit
buffer and completing the close.
aaSetCloseDelay(Dev,MaxDelay)
int Dev Device number
int MaxDelay Maximum time aaClose will
wait for a devices transmit
buffer to drain in seconds. For
no delay use 0. Maximum value
is 32,767 seconds.
int:
NO_ERR if successful.
ERR_DEV if device number out of range.
The device does not need to be open to execute this
function.
Purpose
Call
Return
Comments
aaWrite
Writes serial data out a device.
aaWrite(Dev,Cnt,Buf)
int Dev: Device number
int Cnt: Number of bytes to be
written
unsigned char *Buf: Buffer of data to write
int: Number of bytes written if successful
0 if no data bytes written
ERR_DEV if dev number out of
range
ERR_NOTOPEN if dev not open for
transmit
The Cnt parameter should not be greater than the size
of the Buf transmit buffer.
Purpose
Call
Return
Warning